强激光与粒子束2017,Vol.29Issue(5):26-32,7.DOI:10.11884/HPLPB201729.170042
等离子体天线开启时间光电时差测量法
Light-electricity method for measuring switch-on time of plasma antennas
摘要
Abstract
The optical signals are converted into electrical signals of same time characteristics by the technique of the in-situ spectroscopic detection.The switch-on time is obtained by calculating the time difference of the exciting and electrical signals.Results show that the proposed method can effectively measure the switch-on time of DC and HF AC plasma antennas.The switch-on time of plasma antennas driven by DC and kHz AC power supplies are about 1 ms, and that of plasma antennas driven by MHz power supplies are approximately 0.5 ms.The error of 50 Hz AC plasma antenna is very large due to the unstable discharge state.The value of switch-on time is greatly related to the exciting power and the response time of the power supplies.In a certain range, with the increase of discharge power, the switch-on time of the antenna is shortened.Besides, the error is reduced by about 1%-2%.关键词
等离子体/天线/开启时间/光电时差Key words
plasma/antenna/switch-on time/light-electricity time difference分类
数理科学引用本文复制引用
赵建森,孙洋,倪雨薇,郭晓亮,张芝涛..等离子体天线开启时间光电时差测量法[J].强激光与粒子束,2017,29(5):26-32,7.基金项目
国家自然科学基金项目(51579143) (51579143)
上海市曙光计划(15SG44) (15SG44)
上海市科委项目(16040501700) (16040501700)
中国博士后基金面上项目(2015M581585) (2015M581585)