中国现代医学杂志2017,Vol.27Issue(7):136-138,3.DOI:10.3969/j.issn.1005-8982.2017.07.031
同入路导丝导管辅助技术处理贴壁腔静脉滤器21例报道
Wire and catheter assistant technique in retrieval of 21 tilting and adhesive inferior vena cava filters
李可 1陈克勤 1彭汉武1
作者信息
- 1. 长沙市第一医院,湖南 长沙 410005
- 折叠
摘要
Abstract
Objective To retrospectively summarize the catheter assistant technique via the original vessel access for retrieval of tilting adhesive inferior vena cava filters. Methods From January 2012 to December 2016, totally 21 tilting adhesive inferior vena cava filters were retrieved. A wire and catheter assistant technique was adopted in the procedure to resolve the problem. Re-examination and check-up were performed after the procedure. Results All of the 21 tilting and adhesive filters were retrieved with a mean operation time of 53.3 min. Vessel injury or thrombosis was not observed in the re-examination and check-up. Conclusions Using the wire and catheter assistant technique, tilting adhesive inferior vena cava filters can be safely removed, and the adhesion and tilting can be resolved. This technique can improve the retrieval rate of filters that are hard to remove.关键词
腔静脉滤器/导丝导管辅助/手术技巧Key words
inferior vena cava filter/wire and catheter assistant/operation technique分类
医药卫生引用本文复制引用
李可,陈克勤,彭汉武..同入路导丝导管辅助技术处理贴壁腔静脉滤器21例报道[J].中国现代医学杂志,2017,27(7):136-138,3.