摘要
Abstract
In view of the temperature characteristics of semi circumference heated membrane water-walls in a 350 MW supercritical pressure boiler,a calculation program was built to obtain spiral membrane water-wall temperature distribution under different furnace loads.The results showed that:the uneven distribution of furnace heat load led to uneven heat of water-walls;temperature on the facing flame side of water-walls fluctuated within a narrow range,which was the same as the fin.The distribution of temperature on the facing flame side was low in the middle and higher on other sides.With the increase of height of furnace,temperature of waterwall rose and there was a certain fluctuation.The highest temperature appeared on the facing flame side of the fin,and the lowest temperature appeared on the inner wall of water-wall bus bar when BMCR load was 75%.关键词
超临界锅炉/膜式水冷壁/壁温分布/温度场Key words
supercritical pressure boiler/membrane water-wall/water-wall temperature distribution/temperature field分类
能源科技引用本文复制引用
王为术,崔强,郑梦星,陈刚..350MW超临界机组膜式水冷壁壁温计算[J].郑州大学学报(工学版),2017,38(1):46-49,55,5.基金项目