| 注册
首页|期刊导航|中国医疗设备|使用Daily QA3晨检仪测量气压值的应用分析

使用Daily QA3晨检仪测量气压值的应用分析

柏正璐 时飞跃 秦伟 蒋红兵

中国医疗设备2017,Vol.32Issue(5):73-75,3.
中国医疗设备2017,Vol.32Issue(5):73-75,3.DOI:10.3969/j.issn.1674-1633.2017.05.018

使用Daily QA3晨检仪测量气压值的应用分析

ApplicationAnalysis on Measurement ofAtmospheric Pressure Using Daily QA3

柏正璐 1时飞跃 2秦伟 2蒋红兵1

作者信息

  • 1. 南京医科大学附属南京医院 医疗设备处,江苏 南京210006
  • 2. 南京医科大学附属南京医院 肿瘤放疗中心,江苏 南京210006
  • 折叠

摘要

Abstract

Objective To compare the atmospheric pressure acquired by SNC Daily QA3 with that by barometer and assess the accuracy of pressure value recording by Daily QA3. Methods We selected the measured value of atmospheric pressure around the accelerator acquired by barometer and Daily QA3 at weekly inspection between June 2014 and December 2015, then compared and analyzed the data. Results The value acquired by Daily QA3 is corresponding to that measured by barometer. The difference between the two values is within ±0.5 kPa. Conclusion The precision of atmospheric pressure value given by Daily QA3 is high and it can provide reference for the pressure measurement of radiotherapy.

关键词

大气压/DailyQA3晨检仪/医用加速器/剂量仪/电离室

Key words

atmospheric pressure/Daily QA3/medical accelerator/dosimeter/ionization chamber

分类

能源科技

引用本文复制引用

柏正璐,时飞跃,秦伟,蒋红兵..使用Daily QA3晨检仪测量气压值的应用分析[J].中国医疗设备,2017,32(5):73-75,3.

基金项目

南京市医学科技发展资金"青年工程"人才培养专项经费资助项目(QRX11033). (QRX11033)