云南冶金2017,Vol.46Issue(2):126-131,6.
辉光放电质谱法测定高纯锌中痕量杂质元素
The Determination on Trace Impurity Element in High Purity Zinc byGlow-discharge Mass Spectrometry
杨海岸 1罗舜 1刘英波 1李超 1闫豫昕 1张文娟 1顾松 1阮舒呈1
作者信息
- 1. 昆明冶金研究院,云南 昆明 650031
- 折叠
摘要
Abstract
12 trace impurity elements, such as Mg, Al, Fe, Co, Ni and so on in high purity zinc is determined by glow-discharge mass spectrometry (GD-MS).The optimal working parameters for instrument is obtained, the reasonable sample pretreatment method and the interferential elements might be introduced is discussed, and the interference shall be eliminated by selection of the proper sample pre-sputtering time;the isotope mass spectral line interference existing in determination is discussed, and thus to choose the proper isotope mass spectral line and resolution mode for the elements to be measured, so the effect of interference can be minimized;the high purity zinc product sample is analyzed by Element-GD glow-discharge mass spectrometry with high resolution, the precision degree of determination is discussed, and the detection results are compared with the factory-calibration value, the results show, glow-discharge mass spectrometry is a kind of simple, accurate detection method for high purity zinc material.关键词
辉光放电质谱法/高纯锌/痕量元素检测Key words
glow-discharge mass spectrometry/high purity zinc/trace element determination分类
化学化工引用本文复制引用
杨海岸,罗舜,刘英波,李超,闫豫昕,张文娟,顾松,阮舒呈..辉光放电质谱法测定高纯锌中痕量杂质元素[J].云南冶金,2017,46(2):126-131,6.