For the no-load transformer operating in a 110 kV substation, the abnormal characteristics of magnetizing inrush current waveform output from the electronic current transformer (ECT) are analyzed.According to the transfer characteristic of lossy integrator in the protection current acquisition system of ECT based on Rogowski coil, the analytical expression of the relation between the time constant and the transmission error is derived.Thus an appropriate integration time constant is selected to achieve 5TPE level accuracy of ECT.A simulation model is developed based on the theoretical analysis.After waveform fitting, it is proved that the main reason of abnormal magnetizing inrush current waveform is the improper integrator time constant of ECT.Meanwhile, the simulation also shows that the ECT with a proper integrator time constant has better transient transfer characteristics.

关键词

Rogowski线圈/电子式电流互感器/有损积分器/励磁涌流/时间常数

Key words

Rogowski coil/electronic current transformer/lossy integrator/magnetizing inrush current/time constant

引用本文复制引用

郑玉平,潘书燕,夏雨,王中浪,马玉龙,龙锋..变压器空投时电子式电流互感器输出励磁涌流波形异常分析[J].电力系统自动化,2017,41(9):188-193,6.

电力系统自动化

OA北大核心CSCDCSTPCD

1000-1026

访问量0
|
下载量0
段落导航相关论文