侯顺婷

环境与可持续发展2017,Vol.42Issue(3):125-126,2.
环境与可持续发展2017,Vol.42Issue(3):125-126,2.

AA3连续流动注射法和钼酸铵分光光度法测地表水总磷方法比较

The Comparison of AA3 Continuous Flow Injection Method andmmonium Molybdate Spectrophotometric Method for theDetermination of Total Phosphorus in Surface Water

侯顺婷1

作者信息

  • 1. 上海市普陀区环境监测站,上海 200062
  • 折叠

摘要

Abstract

In this paper,we measured the total phosphorus of surface water by Spectrophotometry with AA3 continuous flow injection and ammonium molybdate,and did comparative analysis. Through this test,it can be seen that the test results difference between the two detection methods of injection AA3 continuous flow and ammonium molybdate spectrophotometric is not big,but the AA3 continuous flow injection method is more automotive,and suitable for large quantities of water sample analysis.

关键词

流动注射仪/地表水/总磷

Key words

flow injection instrument/surface water/total phosphorus