短纯音耳蜗微音电位评估耳蜗功能的临床应用价值

曾凡倩 郑铨艺 柯朝阳

中华耳科学杂志2017,Vol.15Issue(2):157-162,6.
中华耳科学杂志2017,Vol.15Issue(2):157-162,6.DOI:10.3969/j.issn.1672-2922.2017.02.004

短纯音耳蜗微音电位评估耳蜗功能的临床应用价值

Clinical values of tone burst evoked cochlear microphonics in evaluating cochlear function

曾凡倩 1郑铨艺 1柯朝阳1

作者信息

  • 1. 暨南大学第二临床医学院 深圳市人民医院 耳鼻咽喉科 深圳518020
  • 折叠

摘要

Abstract

Objective To compare the presence of tone burst evoked CMs and DPOAEs at corresponding frequen-cies in adult normal and hearing-impaired ears, and determine the clinical value of tone burst evoked CMs in testing hearing in adults. Methods CMs and DPOAEs evoked by 500 Hz, 1000 Hz and 2000 Hz tone bursts were obtained from 68 ears in 34 adults with normal hearing, and from 27 ears in 23 adults with mild hearing loss and 22 ears in 19 adults with moderate hearing loss. The rates of presence of CMs and DPOAEs were compared. Results The rate of CM pres-ence in ears with normal hearing was 100%at 500 Hz and 1000 Hz and 86.76%(59/68) at 2000 Hz, and that of DPOAE presence was 76.47%(52/68) at 500 Hz and 100%at 1000 Hz and 2000 Hz. The rate of CM presence at 500 Hz was higher than that of DPOAE (P<0.05). For ears with mild hearing loss, CMs were present in 85.19%(n=23), 81.48%(n=22) and 37.03%(n=10) of the 27 ears at 500 Hz, 1000 Hz and 2000 Hz, respectively;while DPOAEs were present in 29.63%(n=8), 51.85%(n=14) and 44.44%(n=12) of the ears, respectively. CMs were present in more ears at all tested frequencies than DPOAEs for these ears (P<0.05). For ears with moderate hearing loss, CMs were present in 77.27%(n=17), 77.27%(n=17) and 27.27%(n=6) of the 22 ears at 500 Hz, 1000 Hz and 2000 Hz, and DPOAEs were present in 13.64%(n=3), 40.91%(n=9) and 40.91%(n=9) of the ears at corresponding frequencies, respectively. Again, CMs were present in more ears than DPOAEs at all tested frequencies in these ears (P<0.05). Conclusions The results suggest higher rates of CM detection at middle and low frequencies compared to DPOAEs, which can be used as a supplement to the sometimes difficult to interpret DPOAE evaluation at these frequencies. We recommend combining CMs and DPOAEs in the evaluation of cochlear function.

关键词

耳蜗微音电位/畸变产物耳声发射/短纯音/耳蜗/蜗性聋

Key words

Cochlear microphonics/distortion product otoacoustic emissions/tone burst/cochlea/cochlear deaf-ness

分类

医药卫生

引用本文复制引用

曾凡倩,郑铨艺,柯朝阳..短纯音耳蜗微音电位评估耳蜗功能的临床应用价值[J].中华耳科学杂志,2017,15(2):157-162,6.

中华耳科学杂志

OA北大核心CSCDCSTPCD

1672-2922

访问量2
|
下载量0
段落导航相关论文