口腔疾病防治2017,Vol.25Issue(5):311-315,5.DOI:10.12016/j.issn.2096-1456.2017.05.007
托槽在数字化牙颌模型上位置与间接粘结转移后实际位置的一致性研究
Study on the consistency of the position of the brackets on the digital occlusal model and the actual position af-ter indirect bonding
摘要
Abstract
Objective To provide the experimental basis for the coherence of the indirect bond position by compar-ing the position of the bracket on the digital occlusal model and the position of the transfer to the initial plaster model. Methods Fifteen digitized models were selected for the brackets on the dental denture model, the brackets were trans-ferred to the initial plaster model by indirect bond transfer trays, The line distance between each bracket position in dig-ital dental model and initial plaster model was measured with OrthoRx software. Results The difference between the position of the orthodontic brackets and the position of the initial plaster model was less than 0.20 mm, and the differ-ence was statistically significant (P < 0.05). Conclusion The position of the bracket on the digital occlusal model is consistent with that of the original plaster model, which provides a theoretical basis for digital indirect bonding.关键词
数字化模型/托槽定位/间接粘结/转移托盘/正畸Key words
Digital dental model/Bracket positioning/Indirect bonding/Transfer tray/Orthodontics分类
医药卫生引用本文复制引用
万贤凤,王辉玲,刘震寰,章锦才,段培佳,包丽娜..托槽在数字化牙颌模型上位置与间接粘结转移后实际位置的一致性研究[J].口腔疾病防治,2017,25(5):311-315,5.基金项目
广东省医学科学技术研究基金(A2014606) (A2014606)