南方电网技术2017,Vol.11Issue(3):13-17,5.DOI:10.13648/j.cnki.issn1674-0629.2017.03.003
高压直流输电工程接地系统设计条件优化研究
Research on Design Conditions Optimization of Grounding System in HVDC Project
黄莹 1赵晓斌 1饶宏 1辛清明 1卢毓欣1
作者信息
- 1. 直流输电技术国家重点实验室(南方电网科学研究院),广州510663
- 折叠
摘要
Abstract
Grounding electrode is an important part of HVDC systems, and the determination of design conditions is the key of grounding electrode optimal design.The operational states of grounding electrodes in CSG are researched, and the rules of performance period, number of times and ampere-hour are counted.According to actual running data, the design conditions of conventional grounding electrode are optimized,to effectively reduce the area and cost requirements of conventional grounding electrodes.The concept of short-time grounding electrode conception is proposed, and it's design conditions are put forward according to engineering operation experience for reducing the difficulty of station site selection and improving the economy of grounding electrodes.关键词
高压直流输电/常规接地极/短时接地极/运行电流/运行时间Key words
HVDC/conventional grounding electrode/short-time grouding electrode/operation current/operation time分类
信息技术与安全科学引用本文复制引用
黄莹,赵晓斌,饶宏,辛清明,卢毓欣..高压直流输电工程接地系统设计条件优化研究[J].南方电网技术,2017,11(3):13-17,5.