| 注册
首页|期刊导航|中国临床医学影像杂志|二维高频超声及能量多普勒评价2型糖尿病患者肩袖结构异常改变

二维高频超声及能量多普勒评价2型糖尿病患者肩袖结构异常改变

陶文晖 张宇虹 张萍 苏本利

中国临床医学影像杂志2017,Vol.28Issue(5):359-362,4.
中国临床医学影像杂志2017,Vol.28Issue(5):359-362,4.

二维高频超声及能量多普勒评价2型糖尿病患者肩袖结构异常改变

Evaluation of abnormalities of the shoulder rotator cuff in patients with type 2 diabetes mellitus by two-dimensional high-frequency ultrasonography and power Doppler imaging

陶文晖 1张宇虹 1张萍 1苏本利1

作者信息

  • 1. 大连医科大学附属第二医院,辽宁大连116027
  • 折叠

摘要

Abstract

Objective:To evaluate the value of two-dimensional high-frequency ultrasonography and power Doppler imaging for judgement of the abnormalities of the shoulder rotator cuff in patients with type 2 diabetes mellitus (T2DM).Methods:A total of 60 T2DM patients were enrolled and divided into two groups:group B(30 cases,the course≤10 years),group C(30 cases,the course>10 years).30 healthy subjects were enrolled in group A as normal control.The echotexture of the shoulder rotator cuff and blood flow were observed by two-dimensional high-frequency ultrasonography and power Doppler imaging.The thickness of the long head of the Biceps(BT),Subscapularis tendon(SUB),Supraspinatus tendon(SUP) and Infraspinatus tendon (INF) were measured.Results:The ultrasound imaging of each normal tendon was displayed as string like homogeneous hyperechogenicity interrupted by thin hypoechogenicity in longitudinal section.The abnormal ultrasound findings,such as hypoechoic areas,heterogenous echogenicity,or irregular edges,were more frequently detected in group B than group A of SUP,as well as in group C of BT,SUP,SUB and INF (P<0.05).The ratio of calcification of group B and group C was larger than that of group A (P<0.05).The ratios of abnormalities of the surrounding tissue in BT of group C was larger than that of group A (P<0.05).In both sides,the thicknesses of each tendon in group B and group C were greater than those of group A(P<0.05),and the thicknesses of BT and SUP in the dominant side in group C were greater than those of group B(P<0.05).The thickness of BT in group C were greater in the dominant side than that in the other side (P<0.05).There were no significant difference among the groups of A,B and C in gradings of blood flow.Conclusion:The abnormal echotextures,thickness and internal blood flow of the shoulder rotator cuff in the patients of T2DM can be evaluated by two-dimensional high-frequency ultrasonography and power Doppler imaging objectively.

关键词

糖尿病,2型/肩关节/超声检查,多普勒,彩色

Key words

Diabetes mellitus, type 2/Shoulder joint/Ultrasonography, Doppler, color

分类

医药卫生

引用本文复制引用

陶文晖,张宇虹,张萍,苏本利..二维高频超声及能量多普勒评价2型糖尿病患者肩袖结构异常改变[J].中国临床医学影像杂志,2017,28(5):359-362,4.

中国临床医学影像杂志

OACSTPCD

1008-1062

访问量0
|
下载量0
段落导航相关论文