Abstract
Two methods to measure the output power of inverter was discussed:calculating the output active power by getting the fundamental amplitude and phase of the output phase current through the FFT transform and obtaining the fundamental amplitude and phase of the output phase voltage according to the features of PWM modulation wave;regarding the phase current as fundamental current,and calculating the active power by average the instantaneous power within a period,which came from the sample current multiply PWM modulation value.The FFT method had a strong anti-interference ability to the harmonic current,and could obtain fundamental amplitude and phase accurately,yet it required more CPU resources.The latter method was simple in calculation and required less CPU resources,but it was sensitive to current harmonics.The experiment of the actual system showed that the methods to measure output power of inverter was workable.关键词