安徽农业科学2017,Vol.45Issue(15):85-87,3.
连续流动法测定纸张中六价铬的测量不确定度评定
Uncertainty in Determination of Hexavalent Chromium in Tipping Paper by Continuous Flow Method
赵攀攀 1苏燕 1陆扬 1潘力 1余斐 1朱书秀 1陆明华1
作者信息
- 1. 浙江中烟工业有限责任公司技术中心,浙江杭州 310024
- 折叠
摘要
Abstract
[Objective] In order to evaluate measurement uncertainty for hexavalent chromium in paper of flue-cured type cigarette with continuous flow method.[Method] The process of measurement was analyzed,paper continuous flow method on the determination of hexavalent chromium in causality diagram was revised,the mathematics model was established.The sample preparation,the standard solution preparation,calibration curve fitting,measurement repeatability were analyzed to determine the main sources of the uncertainty of measurement.[Result] The main sources of the uncertainty were the concentration of sample and measurement repeatability.The standardized uncertainty of the measurement result was 0.003 5 mg/kg.Under the confidence level of 95%,when the comprising factor k was equal to 2,the expanded uncertainty was 0.007 0 mg/kg.[Conclusion] The study can provide scientific basis for fully grasping the key factors for the determination of hexavalent chromium content,improving accuracy of determination results.关键词
连续流动法/纸张/六价铬/不确定度Key words
Continuous flow method/Paper/Hexavalent chromium/Uncertainty分类
轻工纺织引用本文复制引用
赵攀攀,苏燕,陆扬,潘力,余斐,朱书秀,陆明华..连续流动法测定纸张中六价铬的测量不确定度评定[J].安徽农业科学,2017,45(15):85-87,3.