| 注册
首页|期刊导航|北京大学学报(医学版)|种植体支抗整体远中移动下颌牙列治疗骨性Ⅲ类错牙合的疗效评价

种植体支抗整体远中移动下颌牙列治疗骨性Ⅲ类错牙合的疗效评价

范少轻 周彦恒

北京大学学报(医学版)2017,Vol.49Issue(3):531-539,9.
北京大学学报(医学版)2017,Vol.49Issue(3):531-539,9.DOI:10.3969/j.issn.1671-167X.2017.03.027

种植体支抗整体远中移动下颌牙列治疗骨性Ⅲ类错牙合的疗效评价

Evaluation of the correction of the skeletal class Ⅲ malocclusion by distalization of the whole mandible dentition with micro-implant anchorage

范少轻 1周彦恒2

作者信息

  • 1. 北京大学口腔医学院·口腔医院, 第一门诊部 口腔数字化医疗技术和材料国家工程实验室 口腔数字医学北京市重点实验室, 北京 100034
  • 2. 北京大学口腔医学院·口腔医院, 正畸科 口腔数字化医疗技术和材料国家工程实验室 口腔数字医学北京市重点实验室, 北京 100081
  • 折叠

摘要

Abstract

Objective:To evaluate the clinical effect of distalizing mandibular dentition with micro-implant in patients with skeletal classⅢmalocclusion.Methods: In the study, 20 patients with skeletal class Ⅲmalocclusion were selected.They are consist of 8 males and 12 female with an age range from 16 to 38 years old and an average age of (21.5±5.6) years.They were treated with straight wire technique and the implant were inserted into the mandibular external oblique line to distlize the lower dentition to a class Ⅰmolar relationships.Cephalometrics films were taken before and after treatment.The changes of hard tissue and soft tissue were analyzed by evaluating 26 measurement measurements.Results: ClassⅠmolar relationships were achieved, and the profile were improved after treatment.ANB increased by(0.80±1.02)°,Wits increased by (1.67±1.74) mm,after treatment(P<0.05).The lower dentition were significantly retracted after treatment with L1-NB distance decreased by(2.64±1.50) mm, P<0.05;the mesial buccal cusp and mesial root of the lower first molars were retracted by (3.26±1.95) mm and (0.79±1.27) mm respectively (P<0.05);the mesial buccal cusp of the lower second molars were retracted by (3.06±1.80) mm (P<0.05).After treatment, mandibular teeth got up-righted distally.From incisors to molar, L1/MP, L5/MP, L6/MP, L7/MP angle decreased by(6.37±8.53)°, (10.59±8.50)°, (11.48±7.22)°, (15.72±7.16)°on average respectively (P<0.05), all of those changes had the statically significant effects.Soft tissue change after treatment, the distance from lower lip to esthetic plane were decreased by (1.70±1.59) mm on average (P<0.05).Conclusion: Distalizing mandibular dentition with micro-implant can get an satisfying result in patients with skeletal class Ⅲmalocclusion, the lower teeth were retracted by controlled tipping movement.

关键词

错牙合/骨性Ⅲ类/种植体支抗/头影测量

Key words

Malocclusion/Skeletal class Ⅲ malocclusion/Implant anchorage/Cephalometry

分类

医药卫生

引用本文复制引用

范少轻,周彦恒..种植体支抗整体远中移动下颌牙列治疗骨性Ⅲ类错牙合的疗效评价[J].北京大学学报(医学版),2017,49(3):531-539,9.

北京大学学报(医学版)

OA北大核心CSCDCSTPCD

1671-167X

访问量0
|
下载量0
段落导航相关论文