| 注册
首页|期刊导航|农业工程学报|脱氮除磷生物滤池填料制备及其对农村生活污水的处理效果

脱氮除磷生物滤池填料制备及其对农村生活污水的处理效果

潘碌亭 谢欣珏 王九成 董恒杰

农业工程学报2017,Vol.33Issue(9):230-236,7.
农业工程学报2017,Vol.33Issue(9):230-236,7.DOI:10.11975/j.issn.1002-6819.2017.09.030

脱氮除磷生物滤池填料制备及其对农村生活污水的处理效果

Preparation of denitrification and dephosphorization biological fillers and its effect on treatment of rural domestic sewage

潘碌亭 1谢欣珏 1王九成 1董恒杰1

作者信息

  • 1. 同济大学现代农业科学与工程研究院,上海 200092
  • 折叠

摘要

Abstract

In the treatment of the rural domestic sewage, the total nitrogen(TN) and total phosphorus(TP) effluent concentration has been too high to comply with the class A ofPollutant Discharge Standard of Municipal Wastewater Treatment Plan(GB18918-2002). To solve this problem, a new type of denitrification and dephosphorization filer adopted in an anoxic filter (AF) - biological aerated filter (BAF) system was developed. The mass percentage of the raw materials of this fillers, namely steel slag, iron scrap, zeolite, activated carbon and cement, was 45%, 10%, 20%, 10% and 15%, respectively. The mixture of these materials at this mass ratio was then wrapped on the hollow float in the coating machine. The final product was produced after curing for a certain time. Due to the fact that the new fillers presented excellent synchronous nitrogen and phosphorus removal performances and were easy to prepare with low cost, they could be beneficial for promotion and application. The scanning electron microscope (SEM) results demonstrated that the fillers were of good hydrophilicity and rough surface. A large number of voids and large specific surface area was conductive to biofilm colonization. Optical microscope results showed that the biofilm was of good growth and high activity, which could remain long-term stable operation without backwash. And five main influencing factors (HRT, gas water ratio, reflux ratio and temperature) were investigated for the advanced treatment research. In the single factor experiment, when the value of the study factor was changed, TN and TP concentrations were measured for consecutive 4 days after the system got stable, and the average value was taken as the final result. The results showed that, within a certain range, the pollutants removal rate was proportional to HRT and temperature which means that the improvement of HRT and temperature exerted a positive effect on pollutant removal within a certain range. Besides, the removal rate tended to increase at first and then decrease with the rising of gas water ratio and reflux ratio. At the same time, the TN removal efficiency was significantly affected by temperature. The TN removal rate experienced an upward then a following downward trend with the increasing of temperature. In contrast, the TP removal rate increased slightly as temperature rose, drawing the conclusion that the changes of temperature had little effect on TP removal. Overall, the optimum conditions of this technology were as follows: HRT 5h, gas water ratio 10:1, reflux ratio 50% and 27℃, which was best for the nitrogen removal. With a stable system operation achieved, the effluent COD (chemical oxygen demand), NH3-N, TN and TP were 18.53, 0.66, 9.78 and 0.30 mg/L respectively and the removal efficiencies were 89.82%, 99.80%, 59.05% and 88.31%, respectively, which could meet the A class criteria specified inPollutant Discharge Standard of Municipal Wastewater Treatment Plan(GB18918-2002). Through the comparative test conducted, the effect of the new filters was better than that of the ordinary commercial ceramic filters, which was of obvious advantages and development prospects. The results have provided reference for the practical engineering and theoretical study.

关键词

污水/脱氮//生物滤池/去除机理

Key words

sewage/denitrification/phosphorus/bio-filter/removal mechanism

分类

资源环境

引用本文复制引用

潘碌亭,谢欣珏,王九成,董恒杰..脱氮除磷生物滤池填料制备及其对农村生活污水的处理效果[J].农业工程学报,2017,33(9):230-236,7.

基金项目

"十一五"国家科技支撑计划项目(2009BAC57B01) (2009BAC57B01)

农业工程学报

OA北大核心CSCDCSTPCD

1002-6819

访问量0
|
下载量0
段落导航相关论文