| 注册
首页|期刊导航|石油化工高等学校学报|加氢裂化换热器结垢腐蚀原因分析

加氢裂化换热器结垢腐蚀原因分析

于焕良 崔蕊 赵耀

石油化工高等学校学报2017,Vol.30Issue(3):15-19,5.
石油化工高等学校学报2017,Vol.30Issue(3):15-19,5.DOI:10.3969/j.issn.1006-396X.2017.03.003

加氢裂化换热器结垢腐蚀原因分析

Fouling Corrosion Analysis of Hydrocracking Heat Exchanger

于焕良 1崔蕊 1赵耀1

作者信息

  • 1. 中国石油化工股份有限公司 天津分公司,天津 300270
  • 折叠

摘要

Abstract

Hydrocracking is one of the commonly used oil processing technology,in which the process conditions are under high temperature and high pressure.For the oil contains sulfur and other impurities,the hydrocracking unit can be corroded easily.The ion chromatography and X-ray fluorescence spectrum are used to study the fouling problem occurred in 2# hydrocracking unit E104 heat exchanger of SINOPEC Tianjin branch,and the causes of the corrosion fouling are analyzed from the scale of mechanism and nature of the material.The effective solving measures of fouling in hydrocracking unit heat exchanger are put forward.

关键词

加氢裂化/换热器/结垢/腐蚀原因/措施

Key words

Hydrocracking/Heat exchanger/Scaled/Corrosion reason/Measure