医疗卫生装备2017,Vol.38Issue(5):92-94,3.DOI:10.7687/j.issn1003-8868.2017.05.092
摄影体位改良对肱骨近端骨折术后的评估价值
Value of improved photography position for post-operative evaluation of proximal humeral fracture
齐叶青 1杜其聪 1杨承欢 1罗春材1
作者信息
- 1. 100853北京,解放军总医院放射诊断科
- 折叠
摘要
Abstract
Objective To compare the values of two photography positions for the evaluation after locking plate implantation of the proximal humeral fracture patient.Methods Totally 200 proximal humeral frature patients after locking plate implantation had the front and lateral shoulder joint X-ray films with the conventional and improved photography positions analyzed retrospectively.Post-operative evaluation was carried out with double-blind method from the aspects of morphology of humeral head,condition of locking plate and screw,humeral head angle and bone cortex around humerus.Results Improved photography position behaved better than the conventional position in displaying morphology of humeral head,condition of locking plate and screw,humeral head angle and bone cortex around humerus.Conclusion Improved photography position is recommended to photograph the lateral side of the locking plate for post-operative evaluation.关键词
数字化X线摄影/肱骨近端骨折/锁定钢板/摄影体位/体位改良/术后评估Key words
digital X-ray photograph/proximal humeral fracture/locking plate/photography position/position improvement/post-operative evaluation分类
医药卫生引用本文复制引用