眼科新进展2017,Vol.37Issue(3):251-254,4.DOI:10.13389/j.cnki.rao.2017.0063
双通道视觉质量系统评估不同方位白内障透明角膜切口手术疗效
Effect analysis of cataract surgery with transparent corneal incision in different direction by dual channel vision quality system
摘要
Abstract
Objective To investigate the effects of cataract surgery with transparent corneal incision in different directions,and discuss the application of dual channel visual quality analysis system in the evaluation of visual quality before and after cataract surgery.Methods Sixty-four patients (64 eyes) with cataract phacoemulsification combined with intraocuiar lens (IOL) implantation were enrolled in our hospital from January to May in 2016,and randomly divided into 2 groups:Group A with corneal incision in the temporal side of the eyes,group B with upper corneal incision.All the cases were examined with standard logarithmic optical acuity and dual-channel optical quality analysis system.The visual acuity,MTF cutoff,Strehl ratio (SR),objective scattering index (OSI) and contrast ratio were compared between the two groups.The OQAS values were 100%,20% and 9%.Results (1) The visual acuity and corrected visual acuity of all patients increased gradually from postoperative 1 day to 1 week (P <0.05),and the visual acuity gradually stabilized after 1 week.The uncorrected visual acuity and corrected visual acuity at postoperative 1 day and 1 week in group A were significantly higher than those in group B at the same time point(P < 0.05).There was no significant difference in uncorrected visual acuity and corrected visual acuity between the two groups at postoperative 1 month and 3 months (P > 0.05).(2) At postoperative 1 day and 1 week,the OSI values of two groups were higher than those before operation,and all the time points were statistically significant (all P < 0.05).The OSI values of group A at postoperative 1 day(2.81 ±0.89) and 1 week(1.98 ±0.73) were significantly lower than those of group B at 1 day(3.46 ± 1.17) and 1 week(2.61 ± 1.20) (all P < 0.05).There was no significant difference in OSI between postoperative 1 month and 3 months (all P > 0.05).The OV9% values of the two groups were increased at postoperative 1 day,1 week,1 month and 3 months,and all the time points were statistically significant(all P<0.05).The value of OV9% in group A at postoperative 1 day(0.29 ±0.09),1 week(0.33 ±0.12),1 month (0.37 ± 0.14) and 3 months (0.42 ± 0.17) were significantly higher than those in group B at 1 day (0.24 ± 0.10),1 week (0.27 ± 0.09),1 month (0.31 ± 0.09) and 3 months (0.34 ± 0.14),which was statistically significant (all P < 0.05).The MTF,SR,OV100% and OV20% values of all the patients were not statistically significant (all P > 0.05).Conclusion In the operation of cataract with the temporal and transparent corneal incision,the postoperative intraocular scattering is small,early visual recovery is fast and the visual quality is high.The long-term effect needs further study.Dual channel visual quality analysis system can further quantify the visual quality parameters,has certain advantage in visual quality assessment.关键词
双通道视觉质量分析系统/角膜切口/白内障/视觉质量Key words
dual channel optical quality analysis system/corneal incision/cataract/visual quality分类
医药卫生引用本文复制引用
陈健,罗玲慧,段国平..双通道视觉质量系统评估不同方位白内障透明角膜切口手术疗效[J].眼科新进展,2017,37(3):251-254,4.基金项目
湖南省2017年卫生计生委科研计划课题(编号:C2017038)Hunan Provincial Health and Family Planning Commission (No:C2017038) (编号:C2017038)