To build a seismic finite element model of the interconnected UHV equipment,the characteristic parameters of restoring force of the sliding fittings for hard bus and the bit-shaped function of flexible bus considering stiffness,must be determined.In this study,quasi-static test was conducted to obtain the restoring force parameters of the sliding fittings,such as the sliding force,the sliding stiffness,and the additional damping ratio.And the bit-shaped function considering the stiffness of flexible bus was deduced via mechanical analysis.Thus,a seismic finite element model of the interconnected UHV equipment was established.Finite element analysis shows that the calculation results of the interconnected UHV equipment are very close to the test data of shaking table,which validates the correctness of the finite element model.This study may provide theoretical and experimental foundation for establishing finite element model of interconnected UHV equipment.关键词
互联特高压设备/抗震性能/位形函数/金具/恢复力特性/有限元模型/验证Key words
interconnected UHV equipment/seismic performance/bit-shaped function/sliding fittings/characteristics of restoring force/finite element model/validation引用本文复制引用
张雪松,卢智成,朱祝兵..互联特高压设备抗震有限元模型的建立与验证研究[J].高压电器,2017,53(6):25-29,5.基金项目
国家自然科学基金青年科学基金项目(51408569) (51408569)
国家电网基金项目(SGKJJSKF(2008)466).Project Supported by National Natural Science Foundation of China(51408569),State Grid Fund(SGKJJSKF(2008)466). (SGKJJSKF(2008)