摘要

Abstract

A typical defect of partial discharge in GIS was analyzed.Ultra high frequency detection,ultrasonic detection and time-of-arrival method were adopted to precisely localize the discharge position with consideration of the equipment structure,and X-ray detection technology was used for nondestructive inspection.The X-ray detection result was consistent with the localized positions obtained by the detection methods mentioned above.In addition,the advantages and disadvantages of the detection methods were summarized,and different combinations of the detection methods were suggested for different detection purposes.

关键词

GIS/局部放电/超高频/超声波/时差法/定位

Key words

GIS/partial discharge/UHF/ultrasonic wave/time-of-arrival method/localization