净水技术Issue(5):63-66,4.DOI:10.15890/j.cnki.jsjs.2017.05.012
超滤-纳滤双膜给水深度处理工艺中试试验
Pilot-Scale Test of Dual Membrane Process of Ultrafiltration-Nanofiltration for Advanced Drinking Water Treatment
车淑娟 1张彩云 1薛涛 1俞开昌1
作者信息
- 1. 北京碧水源科技股份有限公司,北京102206
- 折叠
摘要
Abstract
Aimed at the problem of drinking water pollution and the demand of safer drinking water,a pilot-scale study of ultrafiltration-nanofiltration (UF-NF) process was carried out.As for the effluent of UF process,turbidity,chroma and iron concentration could meet the national drinking water standard,while CODMn,chloride,hardness and ammonia nitrogen could not achieve the standard.As for the NF process effluent,all the items could satisfy the standard.For drinking water treatment,the NF technology maybe safer in terms of water quality,thus will have great potential in the future.关键词
饮用水/给水/超滤/纳滤/深度处理Key words
drinking water/water supply/ultrafiltration(UF)/nanofiltration(NF)/advanced treatment分类
资源环境引用本文复制引用
车淑娟,张彩云,薛涛,俞开昌..超滤-纳滤双膜给水深度处理工艺中试试验[J].净水技术,2017,(5):63-66,4.