天然气与石油2017,Vol.35Issue(3):30-35,6.DOI:10.3969/j.issn.1006-5539.2017.03.007
南八深冷装置分子筛脱水系统优化运行措施
Optimal Operation of Molecular Sieve Dehydration System of Nanba Cryogenic Plant
孙胜勇 1李玉军1
作者信息
- 1. 大庆油田有限责任公司天然气分公司, 黑龙江 大庆 163416
- 折叠
摘要
Abstract
Since Nanba cryogenic plant starts up production at its early stages, several problems have been found about molecular sieve dehydration units, such as the pressure of molecular sieve beds increases or reduces too quickly; the designed regeneration temperatures are not up to standard; the adsorption/regeneration period is unreasonable; the control program is not perfect. Then through theoretical analysis and on-site test, we optimizes the dehydration system, thus the pressure increase/decrease rate is adjusted from 0. 73 MPa/min to 0. 25 MPa/min and the temperature of hot blowing is adjusted from 180℃ to 210℃, and the adsorption/regeneration period is regulated from 8 hours to 12 hours as well. Meanwhile, during the pressure increasing/reducing of molecular sieve beds, the program will be enforced automatically with feedback confirmation to avoid misoperation. Finally, through these improvements, the above problems are effectively solved, ensuring the good running of the molecular sieve dehydration system.关键词
分子筛脱水/升/降压速度/热吹温度/再生周期/控制程序Key words
Molecular sieve dehydration/Pressure increase/decrease rate/Heat blowing temperature/Regeneration period/Control program引用本文复制引用