摘要
Abstract
Low-load reactive power control function of conventional HVDC creates large firing angle or extinction angle of HVDC converter,which increases converter valve stress and power losses.Extinction angle backup control function of LCC-HVDC also leads to system status change and induce power fluctuations.In order to reduce those negative impacts,a reactive power coordinated control strategy for back to back hybrid-HVDC system based on Yunnan asynchronous interconnection project,using fast and precise reactive power control ability of MMC,is proposed.A electromagnetic transient model of Yunnan asynchronous interconnection project is build in PSCAD / EMTDC to verify effectiveness of proposed control strategy.关键词
背靠背混合直流系统/云南异步联网工程/无功协调控制/交流滤波器投切Key words
back to back hybrid-HVDC/Yunnan asynchronous interconnection project/reactive power coordination control/AC filter switching分类
信息技术与安全科学引用本文复制引用
王振,蒋碧松,杨治中,郭春义,李晋伟,陈欢,国建宝..背靠背混合直流的无功协调控制策略研究[J].中国电力,2017,50(6):101-107,7.