| 注册
首页|期刊导航|吉林大学学报(医学版)|磁共振弹性成像对肝纤维化分级诊断价值的Meta分析

磁共振弹性成像对肝纤维化分级诊断价值的Meta分析

牛猛 邓大勇 李云鹏飞 刘硕 丁军

吉林大学学报(医学版)2017,Vol.43Issue(4):787-793,7.
吉林大学学报(医学版)2017,Vol.43Issue(4):787-793,7.DOI:10.13481/j.1671-587x.20170424

磁共振弹性成像对肝纤维化分级诊断价值的Meta分析

Values of MRE in diagnosis of stages of hepaticfibrosis:A Meta-analysis

牛猛 1邓大勇 2李云鹏飞 3刘硕 1丁军1

作者信息

  • 1. 吉林大学中日联谊医院放射线科,吉林 长春 130033
  • 2. 吉林省肿瘤医院放射线科,吉林 长春 130012
  • 3. 吉林大学中日联谊医院麻醉科,吉林 长春 130033
  • 折叠

摘要

Abstract

Objective:To investigate the efficacy and the clinical value of magnetic resonance elastography(MRE) in diagnosis of hepatic fibrosis with Meta-analysis, and to provide basis for clinical treatment of hepatic fibrosis.Methods:The studies published before February 2, 2017 about MRE and staging of hepatic fibrosis in Chinese or English were retrived in the databases including PubMed, EMBase, Web of Science, Cochrane Library,CNKI, CBMDisc,VIP, Wanfang data, and supplemented by manual retrieval for relevant literatures.The inclusion and exclusion criterions were used to select and extract the literatures.The literatures qualitie were valuated based on QUADAS-2 tool.The sensitivity(SEN), specificity (SPE), diagnostic odds ratio (DOR), positive likelihood ratio (+LR), negative likelihood ratio (-LR) on the groups of F0 vs F1-F4,F0-F1 vs F2-F4,F0-F2 vs F3-F4, F0-F3 vs F4 and heterogeneity were combined and tested with Stata software respectively.HSROC and AUROC were also implemented.Results:A total of 1 332 studies were searched, and 22 were included.21 of them were in English and 1 in Chinese.The results of Meta analysis showed that the SENp, SPEp, +LRp,-LRp, DOR and AUROC in F0 vs F1-F4 group were 88.8%(85.0-91.7),95.9%(91.5-98.0),21.435(10.215-44.979),0.117(0.086-0.159),183.187(72.533-462.650) and 0.96(0.94-0.98) ,respectively;the SENp, SPEp, +LRp,-LRp, DOR and AUROC in F0-F1 vs F2-F4 group were 93.3%(89.2%-35.9%), 94.1%(90.2%-96.5%),15.839(9.344-26.848),0.072(0.044-0.117),221.224(100.980-484.648) and 0.98(0.96-0.99),respectively;the SENp, SPEp, +LRp, -LRp, DOR and AUROC in F0-F2 vs F3-F4 group were 92.9%(88.9%-95.5%),94.6%(91.2%-96.8%),17.348(10.496-28.671),0.075(0.048-0.119),230.434(111.482-476.317)0.98(0.96-0.99), respectively;the SENp, SPEp, +LRp,-LRp, DOR and AUROC in F0-F3 vs F4 group were 97.7%(93.0%-99.3%),93.2%(90.3%-95.2%),14.337(9.910-20.742),0.025(0.008-0.075),580.405(144.871-2325.307) and 0.98(0.96-0.99),respectively.Conclusion:MRE,as a new and noninvasive imaging method, has high diagnostic value in all stages of hepatic fibrosis, which can provide a reliable reference for clinical precise treatment of hepatic fibrosis.

关键词

磁共振弹性成像/肝纤维化/肝硬化/Meta分析/诊断效能

Key words

magnetic resonance elastography/hepatic fibrosis/hepatocirrhosis/Meta-analysis/diagnostic efficiency

分类

医药卫生

引用本文复制引用

牛猛,邓大勇,李云鹏飞,刘硕,丁军..磁共振弹性成像对肝纤维化分级诊断价值的Meta分析[J].吉林大学学报(医学版),2017,43(4):787-793,7.

基金项目

吉林省科技厅基础处科研基金资助课题 (200905170) (200905170)

吉林大学学报(医学版)

OA北大核心CSCDCSTPCD

1671-587X

访问量0
|
下载量0
段落导航相关论文