| 注册
首页|期刊导航|电焊机|变压器油箱焊缝试漏方法的对比和探讨

变压器油箱焊缝试漏方法的对比和探讨

沈维洁 翟卫东

电焊机2017,Vol.47Issue(6):110-112,3.
电焊机2017,Vol.47Issue(6):110-112,3.DOI:10.7512/j.issn.1001-2303.2017.06.24

变压器油箱焊缝试漏方法的对比和探讨

Comparison and discussion of several kinds of leakage tests for the welds on transformer oil tank

沈维洁 1翟卫东1

作者信息

  • 1. 西安西电变压器有限责任公司,陕西西安710077
  • 折叠

摘要

Abstract

The leakage of transformer oil tank will cause waste and increase maintenance costs,even affect the product's electrical performance,which brings hidden dangers to the safe operation of the transformer.Three methods of leakage tests commonly adopted by transformer manufacturers for the weld tightness of oil tank are introduced,which are pressure leak test,kerosene penetration leak test and surface dye detection.The detailed operation process of these three methods are described and compared from the aspects of production cost,operation,leakage test effect,characteristics,advantages and disadvantages in actual production.The leakage test method can be determined based on the weld position,welding structure and welding method of transformer oil tank,thus to improve the tightness of welds.

关键词

变压器油箱/焊缝/密封性/渗漏油/试漏

Key words

transformer oil tank/weld/tightness/oil leakage/leakage test

分类

矿业与冶金

引用本文复制引用

沈维洁,翟卫东..变压器油箱焊缝试漏方法的对比和探讨[J].电焊机,2017,47(6):110-112,3.