广东电力2017,Vol.30Issue(6):26-29,4.DOI:10.3969/j.issn.1007-290X.2017.06.006
某电厂矩形尾部烟道数值模拟及截面优化
Numerical Simulation and Cross-section Optimization on Rectangular Tail Flue in Power Plant
卢权 1吕玉坤 1李超 1李文韬 1方远1
作者信息
摘要
Abstract
In allusion to the problem of large resistance in the section from electric precipitator outlet to induced draft fan inlet of the rectangular tail flue of No.2 unit in one power plant, ANSYS fluid calculation software was adopted to perform numerical simulation on flue flow field. Simulation result was compared with theoretical calculation result, which verified reasonability of the research method and drew conclusions that parts with excessive resistance in the flue included parts such as bend or reducer as well as the confluence of flue gas. Three sets of transform scheme for circular cross-section flue were designed and numerical simulation was conducted on resistance characteristic. Resistance reduction rates of the flue of those three schemes were respectively 89.51%, 92.64% and 89.82%. Considering actual engineering application, the scheme of selecting shrimp curved structure was supposed to be appropriate.关键词
尾部烟道/数值模拟/阻力特性/圆截面Key words
tail flue/numerical simulation/resistance characteristic/circular cross-section分类
能源科技引用本文复制引用