The testing rigs of water-based and slurry PCM-based heat pipe solar PV/T cogeneration systems were established to test the temperature of PV panels and heat exchange water tanks, thermal/electric power, thermal/electrical efficiency and comprehensive efficiency. The results showed the average PV panel temperature and water tank temperature of slurry PCM-based heat pipe solar PV/T cogeneration system were 2 ℃ and 1.3 ℃ higher than water-based system, respectively. The daily average thermal, electrical and comprehensive efficiency were 7%, 0.8%and 10.2%higher than water-based system, respectively. This study provided reference for the application of phase change slurry to solar energy storage.

关键词

相变流体/热管式PV/T集热器/热/电效率/综合效率

Key words

phase change slurry (PCS)/heat pipe PV/T solar collector/thermal/electrical efficiency/comprehensive efficiency