可再生能源2017,Vol.35Issue(7):984-989,6.
基于相变流体的热管式太阳能PV/T热电联供系统实验研究
Experimental study on the performance of a slurry PCM-based heat pipe solar PV/T cogeneration system
摘要
Abstract
The testing rigs of water-based and slurry PCM-based heat pipe solar PV/T cogeneration systems were established to test the temperature of PV panels and heat exchange water tanks, thermal/electric power, thermal/electrical efficiency and comprehensive efficiency. The results showed the average PV panel temperature and water tank temperature of slurry PCM-based heat pipe solar PV/T cogeneration system were 2 ℃ and 1.3 ℃ higher than water-based system, respectively. The daily average thermal, electrical and comprehensive efficiency were 7%, 0.8%and 10.2%higher than water-based system, respectively. This study provided reference for the application of phase change slurry to solar energy storage.关键词
相变流体/热管式PV/T集热器/热/电效率/综合效率Key words
phase change slurry (PCS)/heat pipe PV/T solar collector/thermal/electrical efficiency/comprehensive efficiency分类
能源科技引用本文复制引用
陈红兵,栾丹明,褚赛,张磊,李强..基于相变流体的热管式太阳能PV/T热电联供系统实验研究[J].可再生能源,2017,35(7):984-989,6.基金项目
国家重点研发计划项目(2016YFC0700100) (2016YFC0700100)
北京市节能减排协同创新中心项目(02058415002). (02058415002)