星载多角度偏振成像仪非偏通道全视场偏振效应测量及误差分析

钱鸿鹄 孟炳寰 袁银麟 洪津 张苗苗 李双 裘桢炜

物理学报2017,Vol.66Issue(10):32-41,10.
物理学报2017,Vol.66Issue(10):32-41,10.DOI:10.7498/aps.66.100701

星载多角度偏振成像仪非偏通道全视场偏振效应测量及误差分析

Full field of view polarization effect measurement and error analysis of non-polarized channels of spaceborne directional polarimetric camera

钱鸿鹄 1孟炳寰 2袁银麟 3洪津 1张苗苗 3李双 1裘桢炜3

作者信息

  • 1. 中国科学院安徽光学精密机械研究所,合肥230031
  • 2. 中国科学技术大学,合肥 230026
  • 3. 中国科学院通用光学定标与表征技术重点实验室,合肥230031
  • 折叠

摘要

Abstract

The optical system of spaceborne directional polarimetric camera that employs an ultra wide-angle lens for its multiangle,a filter wheel for its multispectral and also its multipolarization capability,a CCD itself for its imaging has a certain polarization effect,which can affect the radiometric accuracy of the non-polarized channels of the instrument.The transmittance of the oblique light rays that are incident on the optical element surfaces is sensitive to the orientation of the electric field,contributing to the linear polarization effect of optical system.The precise polarization measurement and calibration of the passive imaging polarimetry are in urgent need to eliminate the instrumental polarization effect and to improve its radiometric accuracy for observation scenes.The non-polarized channel radiometric model considering the linear polarization effect is deduced in detail by analyzing the instrumental principle and optical structures.Moreover,the reasonably simplified model is established based on the actual lens characteristics.A calibration method in which completely linearly polarized light with different kinds of polarization angles irradiates sparsely the instrument within full field of view and subsequently fits the response in the least square sense,is proposed and simulated.In addition,the measured relative errors of the intensity of incident light with different kinds of polarization states caused by the calibration deviations of instrumental principal physical parameters are analyzed and calculated,such as the azimuthal angle of single pixels,explicit optic polarization rate and low frequency spatial relative transmittance.The actual instrumental parameter values and their calibration deviation amounts are acquired by carrying out the laboratory calibration experiment for instrument and combining the least square fitting.Furthermore,the maximum radiometric calibration relative error caused by the deviation of the physical parameter called explicit optic polarization rate is calculated to be 0.4%,fulfilling completely the requirement of radiometric relative accuracy 5% and retaining abundant tolerance.The study provides a theoretical basis and an experimental guidance in high accurately measuring radiation,calibrating and processing data for the instrumental non-polarized channels with full field of view.

关键词

辐射测量精度/偏振效应/大视场/Stokes-Mueller矩阵

Key words

radiometric accuracy/polarization effect/wide field of view/Stokes-Mueller

引用本文复制引用

钱鸿鹄,孟炳寰,袁银麟,洪津,张苗苗,李双,裘桢炜..星载多角度偏振成像仪非偏通道全视场偏振效应测量及误差分析[J].物理学报,2017,66(10):32-41,10.

基金项目

国家自然科学基金(批准号:41405037)和中国科学院天文联合基金(批准号:U1331111)资助的课题.Project supported by the National Natural Science Foundation of China (Grant No.41405037),and the Astronomical Joint Funds of the Chinese Academy of Sciences,China (Grant No.U1331111). (批准号:41405037)

物理学报

OA北大核心CSCDCSTPCDSCI

1000-3290

访问量0
|
下载量0
段落导航相关论文