Abstract

Objective To improve the manual cleaning quality of digestive endoscope by using DMAIC model. Methods According to the 2004 edition of Endoscopic operation technique of the cleaning and Disinfection Norms issued by the Ministry of Public Health, with the DMAIC model as a guide, the quality improvement measures was conducted, including investigating the status of manual cleaning endoscope, analyzing and verifying the fundamental reason, formulating and implementing the improvement plan and applying effective quality control. The biological test qualified rate, the cleaning operation standard rate, the implementation rate of the protective measures, and the integrity rate of the cleaning and disinfection were recorded. Results After improvement, the biological test qualified ratepassing percent of the endoscopic biology test was increased by 25%, the cleaning operation standard rate the standard rate of cleaning was increased by 13.87%, and the implementation rate of protection was increased by 20.61%, which were significant in statistics (P<0.05). Conclusion Aiming at the problems of the digestive endoscope manual cleaning, the timely adoption of DMAIC model for quality improvement can significantly improve the cleaning quality and reduce the nosocomial infection incidence.

关键词

消化内镜/DMAIC模型/手工清洗/生物学检测/医源性感染

Key words

digestive endoscopic/DMAIC model/manual cleaning/quality improvement/biological test/nosocomial infection incidence

分类

医药卫生

引用本文复制引用

王秋蓉,杨娟,董伟琼,赵红,张晓蓉..基于DMAIC模型的消化内镜手工清洗质量改进研究[J].中国医疗设备,2017,32(7):130-133,4.

中国医疗设备

OACSTPCD

1674-1633

访问量0
|
下载量0
段落导航相关论文