净水技术Issue(6):81-85,5.DOI:10.15890/j.cnki.jsjs.2017.06.014
离子选择性电极法测定污水处理厂进出水中的氨氮含量
Determination of Ammonia Nitrogen in Influent and Effluent of WWTP by Ion-Selective Electrode Method
冀春苗 1王晓爽 2谢一多 1常江 2齐羽3
作者信息
- 1. 北京城市排水集团有限责任公司,北京100124
- 2. 北京市污水资源化工程技术研究中心,北京 100124
- 3. 南京师范大学,江苏南京210046
- 折叠
摘要
Abstract
A method for determination of ammonia nitrogen in influent and effluent from wastewater treatment plants(WWTP) by ionselective electrode was established,and the measurement conditions were discussed for the concentration of ammonia nitrogen in the range of 0.1 ~ 100 mg/L in water samples.Linear correlation coefficients were between 0.999 8 ~ 1.000,detection limit found was 0.004 mg/L,recoveries found was 96.2%~ 103.8%,relative standard deviations (RSD,n =6) found was 0.57% ~ 1.62%.Results between the electrode method and Nessler's reagent colorimetric method were contrasted in the analysis.When ammonia nitrogen concentration of the water samples was greater than 0.5 mg/L and less than 0.5 mg/L,relative average deviations found was less than 5 % and 10 %,respectively.The method is simple,without pretreatment and has good accuracy,precision and reproducibility.It,s suitable for the determination of ammonia in a large number of water samples.关键词
离子选择性电极法/氨氮/进出水/污水处理厂Key words
ion-selective electrode method/ammonia nitrogen/influent and effluent/wastewater treatment plant(WWTP)分类
建筑与水利引用本文复制引用
冀春苗,王晓爽,谢一多,常江,齐羽..离子选择性电极法测定污水处理厂进出水中的氨氮含量[J].净水技术,2017,(6):81-85,5.