压力容器2017,Vol.34Issue(6):64-68,5.DOI:10.3969/j.issn.1001-4837.2017.06.011
蒸汽发生器Ding分析及涡流检测
Ding Analysis and Eddy Current Examination of Steam Generator
王佐森 1程仲贺 1张建磊 1张杰 1李慧博 1刘哲建1
作者信息
- 1. 哈电集团(秦皇岛)重型装备有限公司,河北 秦皇岛 066206
- 折叠
摘要
Abstract
The reason analysis of tube Ding in AP1000 steam generator(SG),which is caused by the deflection of the tube support plates(TSP) during the post weld heat treatment(PWHT) of the two closure seam was introduced.By the mean of simulation Ding test,the relationship of Ding between measurable TSP deformations,Ding size and eddy current signal was found.Based on this relationship,the final quality of heat treatment can be controlled in the process.关键词
AP1000蒸汽发生器/Ding/模拟Ding试验/涡流检测Key words
AP1000 steam generator/Ding/simulation Ding test/eddy current examination分类
机械制造引用本文复制引用