电测与仪表2017,Vol.54Issue(14):53-56,4.
电力线载波通信抗干扰性能测试研究
Research on anti-interference performance test of PLC communication
吴维德 1申杰 1白泰 1李方硕 1向景睿1
作者信息
- 1. 国网四川省电力公司计量中心,成都 610000
- 折叠
摘要
Abstract
The current test equipment of PLC communication performance, which has low accuracy and poor reliability in the aspect of anti-interference performance test.The technical of test system and key technical of anti-jamming test are analyzed.This paper focuses on electromagnetic conduction and radiation crosstalk and multipath interference in the frame of test system, the inaccuracy and instability of LC attenuator and matrix are briefly described, and puts forward the improvement plan.Based on the key components such as high performance EMI filter, shielding box and coaxial programmable attenuator, the existing test system is improved.After the receiving sensitivity and the demodulation threshold SNR test, the test process is more stable, and the test results are more reliable and more precise, the results verify that the improved scheme is suitable for point-to-point communication performance test, and also can be applied to the test of the PLC communication network route capacity.关键词
电力线载波/抗干扰测试/电磁串扰/EMI滤波器/屏蔽箱Key words
PLC/anti-interference test/electromagnetic crosstalk/EMI filter/shielding box分类
信息技术与安全科学引用本文复制引用
吴维德,申杰,白泰,李方硕,向景睿..电力线载波通信抗干扰性能测试研究[J].电测与仪表,2017,54(14):53-56,4.