In order to test and evaluate the performance of multi-spectral imaging system, this research built the multi-spectral imaging system test platform. The each link output radiance of the visible light multi-spectral imaging system test platform based on AOTF is analyzed, and it's calculated the output radiance transmissible efficiency. The platform has been tested and verified, when the MRC is tested in this test platform. The building method and analysis of this test platform maybe has reference meaning for infrared multi-spectral imaging system test.