Abstract
Objective To provide an effective method for the quality of cleaning and disinfection of rigid endoscope based on compared results of two detection methods between the hard endoscope cleaning and disinfection quality. Methods We selected 120 pieces rigid endoscopes which were sterilized and determined qualified by visual method in our department from October 2014 to October 2015. At the same time, the outer surface and the internal cavity of the rigid endoscope was carried on sampling detection using ATP bioluminescence detection and strip method, respectively. Results The surface positive rate of rigid endoscope sterilized by ATP fluorescence detection method was larger than that was sterilized by strip method, but there was no significant difference between the two groups (P>0.05). The internal cavity positive rate and whole positive rate were significantly greater than that of strip method (P<0.05). The RLU value of internal cavity of rigid endoscope was significantly higher than that of instrument surface value. Conclusion A scientific and reasonable testing methods can quickly and objectively evaluate the quality of cleaning and disinfection. ATP fluorescence detection method is simple, rapid and practical, which can improve the quality of hard endoscope cleaning and disinfection.关键词
ATP生物荧光法/杰力试纸法/硬式内镜/清洗消毒Key words
ATP bioluminescence method/strip method/rigid endoscope/disinfection分类
医药卫生引用本文复制引用
李远..不同检测方法在集中式管理硬式内镜清洗消毒质量评估中的价值比较[J].中国医疗设备,2017,32(8):177-179,3.