| 注册
首页|期刊导航|电测与仪表|短时过电流试验设备的校准方法研究

短时过电流试验设备的校准方法研究

王晨 丁恒春 姜振宇 鲁观娜 巨汉基 李亭

电测与仪表2017,Vol.54Issue(15):107-112,6.
电测与仪表2017,Vol.54Issue(15):107-112,6.

短时过电流试验设备的校准方法研究

Research on the calibration of short time over current experiment device

王晨 1丁恒春 2姜振宇 1鲁观娜 2巨汉基 1李亭2

作者信息

  • 1. 国网冀北电力有限公司电力科学研究院计量中心,北京 102208
  • 2. 华北电力科学研究院有限责任公司,北京 100045
  • 折叠

摘要

Abstract

Short time over current effect experiment is significant on testing capability of tolerating instantaneous large current in electrical device, and both on calibrating working performance of smart meters.This paper proposes a novel approach of calibrating the short time over current experiment approach by using current clamp and digital oscilloscope, and describes the method of evaluating measurement uncertainly.This approach, which the calibration precision and uniformity are confirmed through result comparison, can provide important technology base for short time over current effect experiment.

关键词

短时过电流试验/校准/测量不确定度评定

Key words

short time over current experiment/calibration/evaluation of measurement uncertainly

分类

信息技术与安全科学

引用本文复制引用

王晨,丁恒春,姜振宇,鲁观娜,巨汉基,李亭..短时过电流试验设备的校准方法研究[J].电测与仪表,2017,54(15):107-112,6.

基金项目

国家自然科学基金资助项目(51577006) (51577006)