Abstract
In order to improve the output efficiency of PV generation system, an effective maximum power point tracking method of PV array is necessary.And the perturbation and observation (P & O) method is most widely used due to its simplicity and ease of implementation.But there is oscillation around the maximum power point caused by P & O, so this paper proposes an improved variable step size perturbation and observation (P & O) method.The method introduced power P in step change trigger conditions and step form.Variable step regional changed little when the external environment occurred a substantial change, so MPPT can keep the good dynamic and steady state accuracy under different external conditions.It improved the problem that traditional variable step size P & O method can't take into account dynamic and steady state accuracy when the external environment occurs a substantial change.Compared before and after the improvement of the two methods in the simulation and experiment, the results show that the improved variable step size P & O method is correct and effective.关键词
最大功率点跟踪/变步长/扰动观察法/光伏发电系统Key words
maximum power point tracking(MPPT)/variable step size/perturbation and observation (P & O) method/PV generation system分类