航天器环境工程2017,Vol.34Issue(4):376-381,6.DOI:10.3969/j.issn.1673-1379.2017.04.006
温度循环条件下某光电舱结雾现象分析
Analysis of fogging phenomenon in a sealed cabin under
condition of temperature cycling
刘志 1罗吉 1任国华 2卫丽君1
作者信息
- 1. 北京华航无线电测量研究所,北京 100013
- 2. 北京卫星环境工程研究所,北京 100094
- 折叠
摘要
Abstract
Temperature cycle screening is important to improve the product reliability, and the respiration is a main cause of fogging in optoelectronic products, thus the study of fog phenomenon in photoelectric products under the condition of temperature cycle is of significance for similar engineering problems. The low-temperature fogging during the temperature cycle of a sealed chamber is analyzed in detail in this paper. Theoretical calculation and the experiment show that the internal moisture content of the device is the main factor of fogging. The respiration of the chamber's sealed structure has a relatively small effect. Technical improvements can be made based on this finding.关键词
光电试验舱/密封结构/温度循环/水汽含量/呼吸作用/结雾/漏率Key words
photoelectric test tank/sealed structure/temperature cycle/water content/respiration/fogging/leakage rate分类
航空航天引用本文复制引用
刘志,罗吉,任国华,卫丽君..温度循环条件下某光电舱结雾现象分析[J].航天器环境工程,2017,34(4):376-381,6.