可再生能源2017,Vol.35Issue(1):8-12,5.
模拟太阳光源系统的性能测试及实验研究
The performance test and experimental research on sun light source simulating system
摘要
Abstract
A test system of simulated solar light is established by using halogen-tungsten as the light source and setting different lamp positions.Results show that main factor of the un-uniformity of radiation is the arrangement of lights.In this paper,the un-uniformity of radiation of A,B,C types of lamp arrays reaches 4.50%,4.79%,4.23%,respectively.Moreover,radiation intensity varies in a range of 191~307 W/m2.Time and radiation intensity are positive correlation,and the light source unsteadiness of the center and edge of arbitrary point is respectively 0.65% and 0.88%,the others of the arbitrary is 1.02%,which meets the requirements of the relevant solar simulator.关键词
灯阵/模拟太阳光/辐射强度Key words
lamp set/solar simulate/radiation intensity分类
能源科技引用本文复制引用
赵惠忠,宋莎莎,程俊峰,刘雪艳..模拟太阳光源系统的性能测试及实验研究[J].可再生能源,2017,35(1):8-12,5.基金项目
国家自然科学基金项目(50976073) (50976073)
上海市教委科研创新重点项目(13ZZ121). (13ZZ121)