昆明医科大学学报2017,Vol.38Issue(8):106-109,4.
POCT血糖仪与全自动生化分析仪血糖检测结果的对比
Comparative Analysis of Test Results between POCT Blood Glucose Meter and Automatic Biochemical Analyzer
摘要
Abstract
Objective To investigate the correlation between POCT glucose meter and automatic biochemical analyzer test results,to evaluated the reliability of portable POCT blood glucose meter.Methods We vertically collected the blood glucose values that diabetics and non diabetics hospitalized in The First People's Hospital of Qujing of Endocrinology,from January 2012 to December 2015 regularly twice a year,the POCT blood glucose meter and Roche 7600 automatic analyzer test results,all of 448 cases,using SPSS17.0 for statistical analysis. Results The correlation of POCT blood glucose meter test results with Roche 7600 automatic analyzer was coefficiently,r > 0.95,meeting the standards of the Ministry of Public Health.Conclusions POCT glucose meter is simple,rapid,accurate and clinically useful. POCT glucose meter in our department,has good detection accuracy,stability and repeatability.关键词
POCT血糖仪检测/自动生化分析仪检测/纵向/相关性Key words
POCTglucometer detection/Automatic biochemical analyzer detection/Vertical/Correlation分类
医药卫生引用本文复制引用
李贵梅,陈卫文,徐应波,殷晓娥..POCT血糖仪与全自动生化分析仪血糖检测结果的对比[J].昆明医科大学学报,2017,38(8):106-109,4.基金项目
云南省科技厅-昆明医科大学应用基础研究联合专项基金资助项目(2014FZ060) (2014FZ060)