| 注册
首页|期刊导航|农业机械学报|太阳能一地源热泵式沼气工程加温系统TRNSYS模拟

太阳能一地源热泵式沼气工程加温系统TRNSYS模拟

石惠娴 徐得天 朱洪光 张亚雷 孟祥真 郭长城

农业机械学报2017,Vol.48Issue(8):288-295,8.
农业机械学报2017,Vol.48Issue(8):288-295,8.DOI:10.6041/j.issn.1000-1298.2017.08.033

太阳能一地源热泵式沼气工程加温系统TRNSYS模拟

TRNSYS Simulation of Integrated Solar and Ground Source Heat Pump for Biogas Digester Heating System

石惠娴 1徐得天 1朱洪光 2张亚雷 2孟祥真 2郭长城2

作者信息

  • 1. 同济大学新农村发展研究院,上海200092
  • 2. 同济大学国家设施农业工程技术研究中心,上海200092
  • 折叠

摘要

Abstract

The energy structure of energy supply project always adopts traditional and renewable energy together for the past years.However,for the future development,renewable energy will gradually increase the proportion,or even completely replace the traditional energy.The actual energy supply engineering energy utilization effect is worthy of attention.There are two schemes to discuss:engineering test and software simulation.Engineering test will be time-consuming,while software simulation can save a great deal of costs,as well as carry out the design and verification of various control schemes.Therefore,the integrated solar-ground source heat pump for biogas digester heating system simulation was studied.The typical day and year energy utilization effects of the heating system were obtained by using TRNSYS platform with Type109-TMY2 (reader and meteorological data processor),Type71 (vacuum tube solar collector),Type60 (storage tank),Type3b (circulating pump),Type60c (methane),Type668 (heat pump),Type557b (buried pipe),Type14h (operation controller),Type25a (print results) modules.Results showed that in the typically coldest winter day,the total heat supplying capacity was 225.52 M J/d,which included heat pump power consumption (57.24 M J/d),water pump power consumption (13.39 MJ/d),buried tube (71.93 MJ/d) and solar collector (82.96 MJ/d).The total heat dissipation capacity was 208.57 M J/d,which contained biogas pool maintenance structure heat (132 MJ/d) and liquid heating load (76.57 MJ/d).The annual total heat consumption of the system was 46 657.32 M J,the renewable energy included solar contribution (63%) and geothermal contribution (37%),which accounted for 74%.It showed that renewable energy sources were efficiently utilized in the heating system.Furthermore,the system can store 7 630.99 MJ/a of heat to the ground but the heat absorption capacity was 12 954.81 MJ/a.Although the heat storage capacity cannot meet the demand of heat supply,it can alleviate the cold and hot imbalance of soil to some extent.

关键词

沼气工程/加温系统/太阳能-地源热泵式/能耗/TRNSYS模拟

Key words

biogas project/heating system/integrated solar and ground source heat pump/energy consumption/TRNSYS simulation

分类

农业科技

引用本文复制引用

石惠娴,徐得天,朱洪光,张亚雷,孟祥真,郭长城..太阳能一地源热泵式沼气工程加温系统TRNSYS模拟[J].农业机械学报,2017,48(8):288-295,8.

基金项目

国家高技术研究发展计划(863计划)项目(2013AA103006-02) (863计划)

农业机械学报

OA北大核心CSCDCSTPCD

1000-1298

访问量0
|
下载量0
段落导航相关论文