Objective:To explore the methods of automatic quality control of magnetic resonance imaging (MRI), and research the system of detection and control which can provide online assessment report of quality control about results of axis and landscape orientation. Methods: As the testing standards of MRI, the software system that included of client platform and remote online platform was constructed by using MATLAB and C++. The client platform used morphological algorithm, picture segmentation and pattern recognition technique to achieve automatic calculation for 13 kinds of quality control parameters of picture, such as signal-noise ratio, contrast ratio and so on, which obtained from quality control phantom of MRI. The remote online platform saved and uploaded test report through used the format of MySQL database, and it was built on the basis of online big data platform that included local machine, same model machine and the same kind of machine (monthly test and annual test). And then, the quality control report of online assessment was automatically generated after results of axis and landscape orientation was compared.Results:After the system was verified by actual quality control of 50 MRI from various area, model and category, the accuracy testing and assessment reports were obtained. And the system could implement routine automatic calculation and report generation of 13 quality control parameters, and its operation was stable and reliable.Conclusion: The software system, which was designed and applied to automatically calculate image quality and carry out assessment of quality control, can provide a reliable tool for testing stability of long and short term for quality control of MRI.

关键词

质量控制/质量保证/体模/自动计算/线上分析/磁共振成像

Key words

Quality control/Quality assurance/Phantom/Automatic calculation/Online analysis/Magnetic resonance imaging

分类

医药卫生

引用本文复制引用

张春青,赵慧慧,邱建峰,王洪,贺瑶瑶,袁子龙,郭磊,侯坤,彭磊,杨秀云,徐龙春..基于自动计算和线上分析的磁共振成像质量控制系统的研究[J].中国医学装备,2017,14(9):1-5,5.

基金项目

国家重点研发计划"数字诊疗装备"专项(2016YFC0103400)"医学成像与放射治疗中的质量控制体模研发" (2016YFC0103400)

国家重点研发计划"数字诊疗装备"专项(2016YFC0103600)"可溯源至SI单位的磁共振成像系统质控方法及其标准化研究" (2016YFC0103600)

中国医学装备

OACSTPCD

1672-8270

访问量0
|
下载量0
段落导航相关论文