| 注册
首页|期刊导航|中国输血杂志|改良白膜法汇集浓缩少白细胞血小板质量的研究

改良白膜法汇集浓缩少白细胞血小板质量的研究

杜晓明 陈安心 陈丽萍 孔福珠 钱江 何星 庄顺宏

中国输血杂志2017,Vol.30Issue(7):829-831,3.
中国输血杂志2017,Vol.30Issue(7):829-831,3.DOI:10.13303/j.cjbt.issn.1004-549x.2017.07.064

改良白膜法汇集浓缩少白细胞血小板质量的研究

Study on the quality of concentration leukocyte-poor platelet concentrates by improved buffy coat

杜晓明 1陈安心 1陈丽萍 1孔福珠 1钱江 1何星 1庄顺宏2

作者信息

  • 1. 金华市中心血站,浙江金华321000
  • 2. 金华市中心医院
  • 折叠

摘要

Abstract

Objective To investigate the quality of concentrated platelet with less WBC by improved white membrane method,so as to provide the basis for preparation of the concentrated platelet in the future.Methods Testing the quality indicators of 56 cases of concentrated platelet with less white blood cells by improved white membrane method,and comparing the quality indicators of 56 cases of collected platelet at random by machine.Testing the expression rate of platelet membrane surface glycoprotein molecules CD62P and PAC-1 before and after filtering in different storage time,and comparing the expression rate of 37 cases of collected platelets at random by machine.Results The differences of quality indicators between concentrated platelet with less white blood cells by improved white membrane methods and collected platelet at random by machine were not statistically significant (P>0.05),such as volume,platelet content,Ph,amount of RBC mixed within.But The differences of amount of WBC mixed with were statistically significant (P< 0.01),both of sterility tests were negative.The differences of the expression rate of platelet membrane surface glycoprotein molecules CD62P and PAC-1 during storage period within 3 days were not statistically significant (P>0.05).Conclusion The various quality indicators of concentrated platelet with less white blood cells by improved white membrane methods attain mixed concentrated platelet and platelet national standards,and in vitro platelet activity kept well.Platelet special leucocyte filter does not cause obvious platelet activation and damage within three days of storage period of concentrated platelet in filter processing.Collected platelet by machine is being activated and damaged continuously when kept in platelet oscillation device 22±2℃ for 3 days,but activation and damage does not significantly change the platelet activity in vitro.

关键词

汇集血小板/改良白膜法/流式细胞仪/血小板活化

Key words

Concentrate platelet/improved/white membrane method/flow cytometry instrument/platelet activation

分类

医药卫生

引用本文复制引用

杜晓明,陈安心,陈丽萍,孔福珠,钱江,何星,庄顺宏..改良白膜法汇集浓缩少白细胞血小板质量的研究[J].中国输血杂志,2017,30(7):829-831,3.

基金项目

金华市科学技术研究计划项目(项目编号:2010-3-072) (项目编号:2010-3-072)

中国输血杂志

OACSTPCD

1004-549X

访问量0
|
下载量0
段落导航相关论文