| 注册
首页|期刊导航|中国体外循环杂志|经皮移除股动脉插管之新技术心得

经皮移除股动脉插管之新技术心得

刘燕 曹乃文 魏新广

中国体外循环杂志2017,Vol.15Issue(3):172-173,2.
中国体外循环杂志2017,Vol.15Issue(3):172-173,2.DOI:10.13498/j.cnki.chin.j.ecc.2017.03.12

经皮移除股动脉插管之新技术心得

Percutaneous decannulation of venoarterial extracorporeal membrane oxygenation: the experience of new technique

刘燕 1曹乃文 1魏新广1

作者信息

  • 1. 430000 武汉,武汉亚洲心脏病医院体外循环科
  • 折叠

摘要

Abstract

Objective To introduce a new method for the removal of femoral artery intubation.Methods Abbott Perclose Proglide percutaneous vascular stapler,which was usually used for minimally invasive macrovascular stent surgery,was used to remove femoral artery cannula and repair femoral artery in 2 male patients received V-A ECMO support.Results Two cases of patients using percutaneous method were successfully removed femoral artery intubation,with good lower extremity blood flow reviewed by ultrasound and no obvious bleeding complications on intubation sites.Conclusion Percutaneous femoral artery can be removed to avoid the defects of extubation under direct vision and femoral artery suture repair.It is an easy,fast and secure way for extubation,but still needs more cases to verify the current conclusion.

关键词

体外膜肺氧合/动脉插管/新技术

Key words

Extracorporeal membrane oxygenation/Arterial intubation/New technology

引用本文复制引用

刘燕,曹乃文,魏新广..经皮移除股动脉插管之新技术心得[J].中国体外循环杂志,2017,15(3):172-173,2.

基金项目