首页|期刊导航|电力系统保护与控制|光伏电站经柔性直流集电送出系统的低电压穿越协调控制策略

光伏电站经柔性直流集电送出系统的低电压穿越协调控制策略OA北大核心CSCDCSTPCD

Coordinated control strategy between large-scale photovoltaic power station and VSC-HVDC for low voltage ride-through operation

中文摘要英文摘要

光伏电站经柔性直流集电送出系统在交流电网发生故障扰动时应该具备低电压穿越的能力.针对受端和送端交流电网发生故障扰动的情况,提出了一种不依靠通信的光伏电站与VSC-HVDC的低电压穿越协调控制策略.交流电网故障情况下,VSC-HVDC送、受端换流器可依据直流电压的变化量切换控制模式.送端换流器根据VSC-HVDC直流电压的变化量调节光伏电站出口的电压幅值,使光伏电站感受到电压变化并减小有功功率输出,从而迅速维持VSC-HVDC系统的功率传输平衡,提…查看全部>>

Large-scale PV stations integrated with VSC-HVDC should equip with the fault ride-through capability when the AC grid trips.A novel coordinated low voltage ride-through control strategy is proposed between VSC-HVDC and PV stations,which does not rely on communications and can maintain the balance of active power transmission quickly.In case of grid fault,the control modes of HVDC converters can be switched according to the DC voltage variation level.The send…查看全部>>

王岩;魏林君;高峰;刘超;郝全睿;李琰

山东大学电网智能化调度与控制教育部重点实验室,山东济南250061中国电力科学研究院新能源与储能运行控制国家重点实验室,北京100192山东大学电网智能化调度与控制教育部重点实验室,山东济南250061中国电力科学研究院新能源与储能运行控制国家重点实验室,北京100192山东大学电网智能化调度与控制教育部重点实验室,山东济南250061中国电力科学研究院新能源与储能运行控制国家重点实验室,北京100192

柔性直流输电光伏发电故障穿越协调控制策略功率平衡

VSC-HVDCphotovoltaic generationfault ride-throughcoordinate control strategypower balance

《电力系统保护与控制》 2017 (14)

70-78,9

国家电网公司科技项目“青藏高原太阳能集中开发与送出技术经济可行性研究”