Combined process of iron-carbon micro-electrolysis plus aerobic SBBR was used to treat the existing secondary effluent of municipal wastewater treatment.The treatment effect and influencing factors on COD,ammonia nitrogen and TP were investigated.The results showed:when pH value was 5.0~6.0,iron-carbon mass ratio was 2 ∶ 1,porous activated iron was 20 g/L,with the pretreatment of iron-carbon for 1 h,aerobic degradation of SBBR for 2 h,the effluent COD,ammonia nitrogen of secondary biological treatment of municipal wastewater could reach 26 ~ 29,1 ~ 1.4 mg/L respectively,which was far above the first level A criteria specified in Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant (GB 18918-2002).Research results could provide technical reference for upgrading reconstruction of requiring high standards of Municipal sewage treatment plant in environmentally sensitive areas.

关键词

多孔活性铁/铁碳微电解/序批式生物膜反应器(SBBR)/二级出水/组合工艺

Key words

porous activated iron/iron-carbon micro-electrolysis/sequencing batch biofilm reactor(SBBR)/secondary effluent combined processes

分类

建筑与水利

引用本文复制引用

谢慧娜,刘俊新,李杰,孙三祥..“铁碳微电解+好氧SBBR”组合工艺处理城市污水厂二级出水的试验[J].净水技术,2017,(8):37-41,5.

基金项目

国家水体污染控制与治理科技重大专项:北运河流域(北京段)城镇污水处理厂升级改造关键技术研究与示范子课题(2012ZX07203-001) (北京段)

兰州市人才创新创业项目“新型铁碳微电解材料及其应用装置的研发与示范”(2015-RC-76) (2015-RC-76)

净水技术

OACSTPCD

1009-0177

访问量2
|
下载量0
段落导航相关论文