净水技术Issue(8):42-45,4.DOI:10.15890/j.cnki.jsjs.2017.08.008
城市污水污泥深度脱水性能的表征指标
Characteristic Indexes of Deep Dewatering Performance of Urban Sewage Sludge
摘要
Abstract
The feasibility of estimating sludge deep dewatering performance by capillary suction time (CST) and specific resistance to filtration (SRF) was analyzed.And the characteristic indexes of high solid content sludge dewatering-ability were studied.The results indicated that as for high solid content sludge,it was feasible to estimate sludge dewatering-ability by diluting the sludge and testing the CST,while sludge with different solid content could be diluted into the same concentration to compare the dewater-ability.Compared with SRF,CST showed better correlation with water content of dewatered sludge cake,more simple measurement,and better repeatability.Therefore,CST was more preferable to evaluate sludge dewatering ability.关键词
高含固率/城市污水污泥/深度脱水/毛细吸水时间/比阻Key words
high solid content/urban sewage sludge/deep dewatering/capillary suction time(CST)/specific resistance to filtration (SRF)分类
建筑与水利引用本文复制引用
王磊,张辰,谭学军,王逸贤..城市污水污泥深度脱水性能的表征指标[J].净水技术,2017,(8):42-45,4.基金项目
国家水体污染控制与治理科技重大专项(2013ZX07315-003) (2013ZX07315-003)
上海市国际科技合作项目(14230700400) (14230700400)
上海市科技人才计划项目(15XD1522800) (15XD1522800)