纳米材料改善普通干湿喷射混凝土回弹率和强度现场工艺试验

Field Tests on Rebound Ratio and Strength of Ordinary Dry and Wet Shotcrete Mixed with Nano Admixture

丁建彤 1吴勇 1雷英强1

作者信息

  • 1. 中国水利水电第七工程局有限公司,四川 成都610081
  • 折叠

摘要

Abstract

The overall rebound ratio of grade C20-C30 ordinary dry or wet shotcrete tor the side walls and top arch of underground structures are generally about 20% to 30%,and the strength of dry shotcrete is often unqualified.The in-situ spraying tests of such shotcrete in four projects of Beijing-Zhangjiakou Intercity Railway,Baihetan Hydropower Station,Guolangqiao Hydropower Station and Chengdu Subway Line 18 show that,by replacing 10% of cement with HB7-2 inorganic nano admixture developed by Sinohydro Bureau 7 Co.,the rebound ratios of C20-C30 ordinary dry or wet shotcrete can be reduced by 52% to 72% and achieve the level of less than 10%,the maximum spayed thickness in one-pass can reached 30 cm,the initial strength within 24 h is greatly increased,and the 28 d compressive strength is increased by more than 20%.The application of this nano admixture can save at least 0.7 h in each excavation and supporting cycle,therefore,the quality,safety and cost of underground construction can be overall improved.

关键词

纳米材料/喷射混凝土/回弹率/强度

Key words

Nano admixture/shotcrete/rebound ratio/strength

分类

建筑与水利

引用本文复制引用