高压电器2017,Vol.53Issue(9):23-29,7.DOI:10.13296/j.1001-1609.hva.2017.09.005
特高压直流输电直流侧谐波电压测量系统
DC-side Harmonic Voltage Measurement System of Ultra-high Voltage DC Transmission System
汪本进 1焦洋 2徐思恩 1吴士普 1邬文亮 1张明明2
作者信息
- 1. 中国电力科学研究院,武汉430074
- 2. 华中科技大学电气与电子工程学院,武汉430074
- 折叠
摘要
Abstract
The measurement of the harmonic voltage on the DC side of an ultra-high voltage DC (UHVDC) transmission system is of significance for design of the DC-side filter and allocation of the relay protection equipment.In this study,taking a ±1 100 kV DC transmission system as an example,the generation and characteristics of the DC-side harmonic voltage were analyzed,and a harmonic voltage measurement scheme was proposed.Consequently,a DC-side harmonic voltage measurement system was built.Then,a test platform was built to assess the accuracy and the frequency response characteristic of the measurement system,and a data processing algorithm was developed.Test result shows that the measurement system,accompanying with the data processing algorithm,can measure the DC-side harmonic voltage in the range from 50 to 1 200 Hz with an amplitude error smaller than 0.5% and a phase error smaller than 0.5 degree,and it adapts to the frequency fluctuation of power system.关键词
特高压直流输电/谐波电压/测量系统/数据处理算法/适应性Key words
UHVDC/harmonic voltage/measurement system/data processing algorithm/adaptability引用本文复制引用
汪本进,焦洋,徐思恩,吴士普,邬文亮,张明明..特高压直流输电直流侧谐波电压测量系统[J].高压电器,2017,53(9):23-29,7.