| 注册
首页|期刊导航|眼科新进展|睑板腺功能障碍患者的视觉质量分析

睑板腺功能障碍患者的视觉质量分析

余婷 叶芬 施宇华 曹茜 黄振平

眼科新进展2017,Vol.37Issue(10):966-969,4.
眼科新进展2017,Vol.37Issue(10):966-969,4.DOI:10.13389/j.cnki.rao.2017.0245

睑板腺功能障碍患者的视觉质量分析

Evaluation of visual quality in patients with meibomian gland dysfunction

余婷 1叶芬 1施宇华 1曹茜 1黄振平1

作者信息

  • 1. 210000 江苏省南京市,南京总医院眼科
  • 折叠

摘要

Abstract

Objective To evaluate the optical quality in patients with meibomian gland dysfunction (MGD) by using double-pass optical quality analysis system (OQAS-Ⅱ) for offering the reference data for clinical practices.Methods A total of 50 patients with a diagnosis of MGD,who were divided into MGD with dry eye disease (DED) group (n =22) and MGD without DED group (n =28) according to the results of tear film break-up time (BUT) and Schirmer I test (SIT),and another 25 healthy subjects were enrolled in this study.Then several parameters,including modulation transfer function cutoff (MTF cutoff),Strehl ratio (SR) and objective scattering index (OSI),were measured to evaluate the optical quality by using OQAS-Ⅱ.Additional clinical examination,including meibomian gland and tear film assessment were per formed and compared between the three groups.In addition,a correlation analysis was conducted among OSI,MTF cutoff,SR,BUT,SIT and meibomian gland assessment.Results Statistical differences were approached in MTF cutoff,SR,OSI of the three groups (all P < 0.05).The MTF cutoff and SR in MGD without DED group were significantly lower than those in the control group [(31.36 + 1.83) c · deg-1 vs.(35.87 ± 1.59)c·deg-1,(0.21 +0.02) vs.(0.23 ±0.03)],but the OSI got higher [(0.57+ 0.06) vs.(0.45 ±± 0.06)] (all P < 0.05).The SR and MTF cutoff in MGD patients with DED was significantly lower than those in MGD patients without DED [(27.87 ±± 3.08),c·deg-1 vs.(31.36±±1.83)c· deg-1,(0.16 ±±0.02) vs.(0.21 ± 0.02)],but OSIgot significantly higher [(0.72 ± 0.10) vs.(O.57 ± 0.06)] (all P < 0.05).Among the three groups,OSI,MTF cutoff and SR showed no significant correlation with BUT,SIT and meibomian gland assessment (all P > 0.05).Conclusion There is changes in visual quality parameters in MGD patients by OQAS-Ⅱ,and MGD with DED patients has significant changes than MGD patients without DED.

关键词

睑板腺功能障碍/干眼/视觉质量/双通道技术

Key words

meibomian gland dysfunction/dry eye/optical quality/double-pass technique

分类

医药卫生

引用本文复制引用

余婷,叶芬,施宇华,曹茜,黄振平..睑板腺功能障碍患者的视觉质量分析[J].眼科新进展,2017,37(10):966-969,4.

眼科新进展

OA北大核心CSTPCD

1003-5141

访问量0
|
下载量0
段落导航相关论文