中国医疗设备2017,Vol.32Issue(10):97-99,104,4.DOI:10.3969/j.issn.1674-1633.2017.10.026
根本原因分析法在降低软式电子内窥镜故障率中的应用
Application of Root Cause Analysis on Reducing Fault Rate of Flexible Electronic Endoscopy
陈云 1陈慕蓉 2王上东1
作者信息
- 1. 温州医科大学附属第三医院 设备科,浙江 温州 325200
- 2. 温州医科大学附属第三医院 内窥镜中心,浙江 温州 325200
- 折叠
摘要
Abstract
This paper firstly introduced the basic structure and common faults of flexible electronic endoscopy, then found out reasons for high fault rate with root cause analysis. And relevant improvement plans was further developed and implemented. As a result, the faulty rate declined obviously and efficiency was improved.关键词
根本原因分析法/软式电子内窥镜/故障率/医疗设备管理Key words
root cause analysis/flexible electronic endoscopy/fault rate/medical equipment management分类
医药卫生引用本文复制引用
陈云,陈慕蓉,王上东..根本原因分析法在降低软式电子内窥镜故障率中的应用[J].中国医疗设备,2017,32(10):97-99,104,4.